60 007-5536-001
A: Technical Specifications
Environmental Specifications
Table A-2 lists the environmental specifications of the system.
Table A-2 Environmental Specifications
Feature Specification
Temperature tolerance
(operating)
+5 °C (41 °F) to +35
°C (95 °F) (up to 1500 m / 5000 ft.)
+5 °C (41
°F) to +30
°C (86
°F) (1500 m to 3000 m /5000 ft. to 10,000 ft.)
Temperature tolerance
(non-operating)
-40 °C (-40 °F) to +60
°C (140 °F)
Relative humidity 10% to 80% operating (no condensation)
8% to 95% non-operating (no condensation)
Cooling requirement Ambient air or optional water cooling
Maximum altitude 10,000 ft. (3,049 m) operating
40,000 ft. (12,195 m) non-operating
Acoustical noise level Less than 65 dBa maximum