System Control
007-4603-001 19
System Control
The functions of SGI Origin 3900 system control are to:
• Manage power control and sequencing
• Provide environmental control and monitoring
• Initiate system resets
• Provide storage for identification and configuration information
• Provide a console/diagnostic and scan interface
SGI Origin 3900 system control comprises three levels:
• L1 controller - brick-level system controller
• L2 controller - rack-level system controller
• L3 controller - system-level controller
L1 Controller
The L1 controller is not configurable; it is an internal design feature of all bricks except
the D-brick.
L2 Controller
The L2 controller is required with all SGI Origin 3900 systems. The L2 controller is a
5.5 in. x 11.1 in. PCB assembly that is mounted in the top of the rack. The L2 controller
does not use configurable rack space. It receives 48-VDC power (30 watts) from the
power bay.
L3 Controller
The L3 controller is a system-level controller. The L3 controller is SGI software that runs
on a stand-alone workstation or laptop computer. The L3 connects to the L2 controllers
via a 10BASE-T Ethernet hub. The L3 controller is optional.